The TriStar uses a set of LEDs to communicate information to the user. A list of statuses, faults, and alarms is listed below.
LED Indicator
G | Green LED is lit |
Y | Yellow LED is lit |
R | Red LED is lit |
G/Y | Green and Yellow are lit at the same time |
G/Y - R | Green and Yellow both lit, then Red is lit alone |
Status, Faults, and Alarms
LED | Status |
General Transitions | |
G-Y-R | System Startup |
G/Y/R-G/Y/R-G (one cycle) | Push button equalize start |
G/Y/R-G.Y.R-R (one cycle) | Push button equalize stop |
All 3 LEDs blinking | Battery service required |
Battery Status (SOC will not be accurate for lithium) |
|
G | 80-95% SOC |
G/Y | 60-80% SOC |
Y | 35-60% SOC |
Y/R | 0-35% SOC |
R | Battery is discharging |
G blinking (1/2 second) | Absorption |
G fast blink (2-3 times per second) | Equalization |
G slow blink (1 second) |
Float |
Faults & Alarms |
|
R/G-Y |
Short circuit - solar/load |
R/Y-G |
Overload - solar/load |
R-Y |
Over-temperature |
R-G |
High voltage disconnect |
no LEDs |
Reverse polarity - battery |
no fault indication |
Reverse polarity - solar |
R-Y-G |
Dipswitch fault |
R-Y-G |
Self test fault |
R/Y-G/Y |
Temperature probe (RTS) |
R/Y-G/Y |
Battery voltage sense |
If you are receiving persistent alarms and cannot resolve the issue, take photos of your electrical system and email them to support.enerdrive@dometic.com along with a brief description of the LED fault sequence and problems you are encountering.