The product packaging has been misprinted with 'Total 100A 32V maximum - 20A maximum per circuit' instead of 'Total 50A 32V maximum - 15A maximum per circuit'. As a result the fuse block may be under-rated for certain applications and use cases. Under some circumstances if current draw through the fuse block is above 50A, it could lead to a fire, or produce soot, smoke, and melting of the fuses and fuse block.